PRODUCTS


Schaeffler
OPTIME-LW-C1
Automatic lubrication system OPTIME-LW-C1
加入詢價
科技數據
Piston pump
Functional principle
VLub
60 / 125 cm³
Lubricant volume
≈ 0,5 cm³
Metering volume per lubrication interval
0,17 – 8,3 cm³
Metering volume per day
pop
10 bar
Operating pressure, max.
≤ NLGI 2 (suitability test required)
Lubricant
nout
1
Number of outlets
1
Number of lubrication points: direct
Uop
6-V alkaline battery
Operating voltage
OPTIME
Controller (integrated)
via OPTIME
Monitoring: fill level
1 up to 12 months
Dispensing time cartridge
Empty level, back pressure, internal error: via OPTIME
Error message
NFC
Commissioning
2.4 GHz
Wirepas Mesh (ISM band)
100 m
Line of sight range
IP68
Protection class
Polyethylenterephthalat (PET)
軸承座 material
tmin
-10 °C
Operating temperature, min.
tmax
55 °C
Operating temperature, max.
arbitrary
Mounting position
Connection thread
60 x 60 x 93
Dimensions (mm)
≈m
0.26 kg
重量

附加資訊
10x OPTIME C1, 10x battery pack, 1x OPTIME C1 prefill nipple; lubricant cartridge CONCEPT1 not included
供貨範圍 per package
EU-Members, Israel, Republic of Macedonia, Norway, Saudi Arabia, Switzerland, Turkey, UK, India, Vietnam, Colombia, Peru
Country approvals
加入詢價